TICO-MFH-230VAC-R-2 Digital Counter 6-Digit “Hengstler”

Very simple operation
Four different backlighting colours
Large, easily read display
Counting frequency up to 60 kHz
Three presets
Prescaler 0.0001 – 99.9999
Product Family tico 772
Function
Totalizing Counter
Preset Counter
Multifunctional Counter
Tachometer
Position Indicator
Technology Electronic
Display
6-digit
double spaced
Counter-Reading/Presets
Pre-Zero Rejection
Decimal Point(up to 4 Positions after Decimal Point)
Digit Height [mm]
8. Line 9,3 ,
2. Line 7,2
Display Variant LCD reflective
View Angle 12 o’clock
Relay 2
Reset
Manual Reset
Electrical Reset
Automatic Reset
Signal Times 0,01 s to 599,99 s or bistable programmable, Tolerance + 10ms, active on or off
Current Consumption [mA] < 50 , including Sensor Supply Power Consumption < 5 W Cable Cross-Section 1...1,5 mm² with Cable End Sleeve Input Resistance Approx. 10 kOhm Pulse Length min. 17 ms (30 Hz), 8 ?s (60 kHz) Supply Voltage 230 VAC ± 10% 50/60 Hz Count Frequency [Hz] max. 60 kHz (TTL 20 kHz): Single Channel Counting and Input max. 60 kHz (TTL 20 kHz): Difference- or Adding-Operation Channel (A+B together) max. 30 kHz (TTL 20 kHz): Phase Discriminator Input with single or double Evaluation max. 15 kHz (TTL 15 kHz): Phase Discriminator Input with quadruple Evaluation energized 30 Hz More Details see Drawing and Operating Instruction Overload Protection ext. Protection 32 mAT Sensor Supply 12-24 VDC (load-dependent) max. 50 mA Storage of Values NV-Storage > 10 Years
Electrical Connection Plug-In Screw Terminals / Connecting Terminals
Amplitude Threshold
< 2 V and > 8 V or < 1 V and > 4 V at TTL-Level
Amplitude max. 40 VDC
Active Edge
programmable positive on PNP-Input
negative on NPN-Input
Pulse Shape Optional (max. Frequency Rectangle 1:1)
Prescaler 0,0001 – 99,9999
Set Function Set on Preset 0 (Independent of Reset)
Display and Preset Range – 999 999 to + 999 999
Alarm Signal Display blinks when Preset 0,1 or 2 are active
Relay (Preset 1 and 2)
Changeover Contact max. 250 VAC / 30 VDC / 5 A
Changeover Contact min. 5 VAC / 5 VDC / 10 mA
Delay < 10 ms Transistor output (Preset 1 + 2) PNP-Output 12 - 24 VDC max. 30 mA Application Output PNP-Output 12 - 24 VDC max. 20 mA Attention Current Load of Output (Sensor 12-24 VDC out1 out2 Appl.-Outp.) cannot be higher than 65 mA in total Counter Mode Input A,B Single Channel add or sub, Channel Input, Differencial Operation add / sub, Adding Operation add / add, Phase Discriminator single, double or quadruple Evaluation Preselect Modes Absolute or Trailing Preset Signal/Limit Values (Sign. 1 < Preset 1 Sign. 2 > Preset 2)
Application Input/Output (Counter)
Output: Prescaler-out
Preset 0-out
Direction-out
Input: additional Counting Input add / sub
Reset
Setting
Gate
Keylock
Hold
Teach in
Mode Batch Counter with Preset or 2. Totalizing Counter with Preset
Count Mode
Differencial Operation add/sub
Adding Operation add/add
Measuring Principle (tachometer) Period Measuring Principle
Display Range 1/min or 1/sec
min. Frequency 1 Hz or 0,1 Hz
Limit Values
2 Alarms with programmable Start-Up Suppression
+ 1 additional higher Limit Value on Application Output
Tachometer Mode of Operation
Single Channel add or sub, Channel Input
Differencial Operation add / sub
Adding Operation add / add
Phase Discriminator single, double or quadruple Evaluation
A / B or (A-B) / A %
Application Input/Output (Tachometer)
Output: Preset 0-out
Direction-out
Input: additional Counting Input add / sub
Gate
Keylock
Hold
Teach in
Accuracy of the Tachometer Function
Time Base: ± 30 ppm
Measuring Principle: Period Measuring
Measuring Time: min. 0,5s / max. 1s or 10s
Measuring Resolution: 0
4?s (<30 ppm) Display Resolution: 4 Positions after Decimal Point 1 Digit = 100 ppm Overall Tolerance (Tachometer) Display Resolution + Tolerance Time Base = 130 ppm Time Base (Tachometer) programmable, sec min. h or hh.mm.ss Measuring Principle (timer) Impulse Width- or Period Measuring (start-stop) Start Inp. A + Stop Inp. B, Start/Stop-Button Function Time Counter Single Pulse Measuring or Cumulated Measuring Application Input/Output (Timer) Output: Preset 0-out Input: additional Run Stop Reset Setting Keylock Hold Teach in Accuracy of the Timer Time Base. ± 30 ppm Start / Stop-Time: 16 ?s / 16 ms (unenergized / energized) Resolution: 100 ?s = 100 ppm Overall Tolerance (Timer) Display Resolution + Tolerance Time Base = 130 ppm Resolution 1, 0,1, 0,01, 0,001, 0,0001 Operating Temperature [°C] 0°... 50 EN 60 068-2-1/2 Storage Temperature [°C] - 20°... + 65 EN 60 068-2-1/2 Degree of Protection IP 65 Front Panel, EN 60529 IP 20 Connections Cable Length * Cable Length >30m
Connection to Direct Current Line Voltage and Input Level TTL makes an additional Protective Circuit necessary
General Design EN 61 010-1 / IEC 61010-1
EMC – Interference immunity EN 61326-1 Industrial Sector **
EMV-Emission EN 61326-1 Class B*
Approvals
UL
CSA File-Nr. E 338588
Vibration Resistance 10 m/s² (10 … 150 Hz), EN 60 068-2-6
Shock Resistance 100 m/s² (18 ms), EN 60 068-2-27
Protection Class II, EN 61010-1 / IEC 61010-1
Contamination Level
V 2
EN 50178
Climate
40°C / 93% RLF class 4K4H
EN 60 068-2-78
25 – 50°C / 93% RLF
cyclic
EN 60 068-2-38
Height until 2000 m
Resistence to Chemicals Frontfoil as per DIN 42 115-2
RoHS conform
Size [mm] 48x48x118
Mounting Options Frame
Mounting with Frame
Reset
Manual Reset via Keyboard
External Reset static or dynamic
Pulse Duration min. 5 ms
Automatic Reset after Reaching Preset 2
at max. Counting Frequency no Pulse Loss by Automatic Reset. via Application Access (programmable) and Set-Up Reset (programmable)
Weight [g] Approx. 200
Dimensions [mm]
48
CSA x 48
CSA x 118
CSA
Mountingdepth 110
CSA
DIN 43 700
Panel Thickness [mm] max. 11

REF: 0772132 Categoria: