Autosimatic - Grupo Luminag

101153919 – Schmersal

101153919 – Schmersal

STOCK: 0.00 unidade(s)
SE-100 C Evaluation Unit Stop 0 Monitor 1-2 “Schmersal”

1 Signalling output
eCl@ss number, version 12.0
27-37-18-19
eCl@ss number, version 11.0
27-37-18-19
eCl@ss number, version 9.0
27-37-18-19
ETIM number, version 7.0
EC001449
ETIM number, version 6.0
EC001449
Approvals – Standards
Certificates
TÜV
cULus
General data
Standards
EN ISO 13849-1
EN ISO 13850
Climatic stress
EN ISO 13856-2
Housing material
Plastic, PE (Black), Crastin (Grey)
Reaction time, maximum
16 ms
Gross weight
166 g
General data – Features
Stop-Category
0
Electronic Fuse
Yes
Wire breakage detection
Yes
Cross-circuit detection
Yes
Automatic reset function
Yes
Reset after disconnection of supply voltage
Yes
Earth connection detection
Yes
Integral system diagnostics, status
Yes
Number of auxiliary contacts
1
Number of LEDs
2
Number of safety contacts
1
Number of signalling outputs
1
Safety classification
Performance Level, up to
c
Category
1
Control category to EN954
1
PFH value
2.24 x 10?6 /h
Note (PFH-value)
up to max. 5,000 switching cycles/year
Mission time
20 Year(s)
Mechanical data
Mechanical life, minimum
20,000,000 Operations
Mounting
Snaps onto standard DIN rail to EN 60715
Mechanical data – Connection technique
Length of cable
200 m
Termination
Screw terminals M20 x 1.5
Cable section, maximum
2 x 1.5 mm²
Note (Cable section)
All indications including the conductor ferrules.
Mechanical data – Dimensions
Width
22.5 mm
Height
100 mm
Depth
121 mm
Ambient conditions
Degree of protection of the enclosure
IP40
Degree of protection of the mounting space
IP54
Degree of protection of clips or terminals
IP20
Ambient temperature
+5 … +55 °C
Resistance to vibrations
10 … 55 Hz, amplitude 0.15 mm
Ambient conditions – Insulation values
Rated impulse withstand voltage Uimp
4 kV
Overvoltage category
III
Degree of pollution
2
Electrical data
Operating voltage
24 VDC -10 % / +20 %

Rated operating voltage
24 VDC
Operating current
150 mA
Rated AC voltage for controls at DC minimum
21.6 VDC
Rated control voltage at DC, maximum
28.8 VDC
Utilisation category AC-15
230 VAC
Utilisation category AC-15
2 A
Utilisation category DC-13
24 VDC
Utilisation category DC-13
2 A
Electrical power consumption, maximum
4 W
Time to readiness, maximum
300 ms
Electrical data – Electromagnetic compatibility (EMC)
EMC rating
EMC-Directive
Status indication
Indicated operating states
Safety edge function
Other data
Note (applications)
Safety edges
Note
Note (General)
The overall machine safety depends on the professional mounting and installation of the safety monitoring module and the signal transmitter, as well as on the correct and professional electrical connection of the components.
If there it any risk whatsoever, the machine may not be restarted.
Wiring example
Note (Wiring diagram)
Monitoring the safety edges SE 40 / SE 70 with a safety monitoring unit SE-100C up to PL c and Category 1.
If only one safety edges is connected, the terminals S12/S22 must be bridged.
The manual reset function, if required, is realised by the machine control.
Both re-initialisation and auto-reset must comply with the requirements of EN 1760-2 (diagram A2, A3).
The wiring diagram is shown for the de-energised condition.

REF: 101153919 Categoria: