Autosimatic - Grupo Luminag

103001411 – Schmersal

103001411 – Schmersal

STOCK: 0.00 unidade(s)
AZM300B-ST-1P2P-A Universal Coding with RFID “Schmersal”

EAN: 4030661425931
Connector M12, 8-pole
Power to lock
Actuator monitored
Diagnostic output
hygienic design
Protection class IP 69
Suitable for mounting to profile systems
Thermoplastic enclosure
RFID-technology for needs-based protection against tampering
3 different directions of actuation
Compact design
3 LEDs to show operating conditions
Suitable for hinged and sliding guards
Series-wiring
Manual release
eCl@ss number, version 12.0
27-27-26-03
eCl@ss number, version 11.0
27-27-26-03
eCl@ss number, version 9.0
27-27-26-03
ETIM number, version 7.0
EC0z
ETIM number, version 6.0
EC002593
Approvals – Standards
Certificates
TÜV
cULus
ECOLAB
EAC
FCC
IC
General data
Standards
EN ISO 13849-1
EN ISO 14119
EN IEC 60947-5-3
EN IEC 61508
Coding
Universal coding
Coding level according to EN ISO 14119
Low
Working principle
RFID
Frequency band RFID
125 kHz
Transmitter output RFID, maximum
-6 dB/m
Enclosure material
Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Gross weight
600 g
Time to readiness, maximum
5,000 ms
Duration of risk, maximum
200 ms
Reaction time, switching off safety outputs via actuator, maximum
100 ms
Reaction time, switching off safety outputs via safety inputs, maximum
1.5 ms
General data – Features
Power to lock
Yes
Actuator monitored
Yes
Latching
Yes
Manual release
Yes
Short circuit detection
Yes
Cross-circuit detection
Yes
Series-wiring
Yes
Safety functions
Yes
Integral system diagnostics, status
Yes
Number of fail-safe digital outputs
2
Safety classification
Standards
EN ISO 13849-1
EN IEC 61508
Safety classification – Interlocking function
Performance Level, up to
e
Category
4
PFH value
5.20 x 10?¹° /h
PFD value
4.50 x 10?5
Safety Integrity Level (SIL), suitable for applications in
3
Mission time
20 Year(s)
Mechanical data
Mechanical life, minimum
1,000,000 Operations
Note (Mechanical life)
When using as door stop: = 50.000 operations (door mass = 5 kg and actuating speed = 0.5 m/s)
Angular misalignment between solenoid interlock and actuator, maximum
2 °
Holding force FZh in accordance with EN ISO 14119
1,150 N
Holding force Fmax, maximum
1,500 N
Latching force, adjustable, position 1
25 N
Latching force, adjustable, position 2
50 N
Type of the fixing screws
2x M6
Tightening torque of the fixing screws, minimum
6 Nm
Tightening torque of the fixing screws, maximum
7 Nm
Mechanical data – Switching distances according EN IEC 60947-5-3
Assured switching distance “ON” Sao
1 mm
Assured switching distance “OFF” Sar
20 mm
Switch distance, typical
2 mm
Mechanical data – Connection technique
Termination
Connector M12, 8-pole, A-coded
Length of sensor chain, maximum
200 m
Note (length of the sensor chain)
Cable length and cross-section change the voltage drop dependiing on the output current
Note (series-wiring)
Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD
Mechanical data – Dimensions
Length of sensor
120 mm
Width of sensor
87.5 mm
Height of sensor
35 mm
Ambient conditions
Degree of protection
IP67
IP69
IP66
Ambient temperature, minimum
+0 °C
Ambient temperature, maximum
+60 °C
Storage and transport temperature, minimum
-10 °C
Storage and transport temperature, maximum
+90 °C
Relative humidity, maximum
93 %
Note (Relative humidity)
non-condensing
non-icing
Resistance to vibrations
10 … 150 Hz, amplitude 0.35 mm
Restistance to shock
30 g / 11 ms
Protection class
III
Permissible installation altitude above sea level, maximum
2,000 m
Ambient conditions – Insulation values
Rated insulation voltage Ui
32 VDC
Rated impulse withstand voltage Uimp
0.8 kV
Overvoltage category
III
Degree of pollution
3
Electrical data
Operating voltage, minimum
20.4 VDC
Operating voltage, maximum
26.4 VDC
Note (Power supply, general)
stabilised PELV power supply
No-load supply current I0, maximum
100 mA
Current consumption with magnet ON, average
200 mA
Current consumption with magnet ON, peak
350 mA / 200 ms
Required rated short-circuit current
100 A
External wire and device fuse rating
2 A gG
Switching frequency, maximum
0.5 Hz
Electrical data – Magnet control
Designation, Magnet control
IN
Switching thresholds
-3 V … 5 V (Low)
15 V … 30 V (High)
Current consumption at 24V
10 mA
Magnet switch-on time
100 %
Test pulse duration, maximum
5 ms
Test pulse interval, minimum
40 ms
Classification ZVEI CB24I, Sink
C0
Classification ZVEI CB24I, Source
C1
C2
C3
Electrical data – Safety digital inputs
Designation, Safety inputs
X1 and X2
Switching thresholds
-3 V … 5 V (Low)
15 V … 30 V (High)
Current consumption at 24V
5 mA
Test pulse duration, maximum
1 ms
Test pulse interval, minimum
100 ms
Classification ZVEI CB24I, Sink
C1
Classification ZVEI CB24I, Source
C1
C2
C3
Electrical data – Safety digital outputs
Designation, Safety outputs
Y1 and Y2
Design of control elements
short-circuit proof, p-type
Voltage drop Ud, maximum
2 V
Leakage current Ir, maximum
0.5 mA
Voltage, Utilisation category DC-12
24 VDC
Current, Utilisation category DC-12
0.25 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
0.25 A
Test pulse duration, maximum
0.5 ms
Test pulse interval, typical
1000 ms
Classification ZVEI CB24I, Source
C2
Classification ZVEI CB24I, Sink
C1
C2
Electrical data – Diagnostic outputs
Designation, Diagnostic outputs
OUT
Voltage drop Ud, maximum
2 V
Voltage, Utilisation category DC-12
24 VDC
Current, Utilisation category DC-12
0.05 A
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
0.05 A
Status indication
Note (LED switching conditions display)
Operating condition: LED green
Error / functional defect: LED red
Supply voltage UB: LED green
Pin assignment
PIN 1
A1 Supply voltage UB
PIN 2
X1 Safety input 1
PIN 3
A2 GND
PIN 4
Y1 Safety output 1
PIN 5
OUT Diagnostic output
PIN 6
X2 Safety input 2
PIN 7
Y2 Safety output 2
PIN 8
IN Solenoid control
Scope of delivery
Scope of delivery
Actuators must be ordered separately.
Accessory
Recommendation (actuator)
AZ/AZM300-B1
Note
Note (General)
For doors that are flush with the door frame, the optional mounting plate MP-AZ/AZM300-1 can be used
For glass and Makrolon doors, the optional mounting kit MS-AZ/AZM300-B1-1 can be used
As long as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. In this case, the safety outputs are re-enabled, so that the safety guard must not be opened
EU Declaration of Conformity LOG_COM_lo1de01s
Original
K.A. Schmersal GmbH & Co. KG
Möddinghofe 30
42279 Wuppertal
Germany
Internet: www.schmersal.com
Erklärung: We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives.
Bezeichnung des Bauteils: AZM300
Type: See ordering code
Description of the component: Interlocking device with electromagnetic interlock for safety functions
Relevant Directives: 2006/42/EG Machinery Directive
2011/65/EU RoHS-Directive
2014/53/EU RED-Directive
Aplied standards: IEC 60947-5-3:2013,
EN ISO 14119:2013,
EN 300 330 V2.1.1:2017,
EN ISO 13849-1:2015,
IEC 61508 Teile 1-7:2010
Notified body for the prototype test: TÜV Rheinland Industrie Service GmbH
Am Grauen Stein, 51105 Köln
ID n°: 0035
EC-prototype test certificate: 01/205.5281.03/20
Person authorised for the compilation of the technical documentation: Oliver Wacker
Möddinghofe 30
42279 Wuppertal
GRA_SIG_ksig-y24
Authorised signature
Philip Schmersal – Managing Director

REF: 103001411 Categoria: