Autosimatic - Grupo Luminag

103016752 – Schmersal

103016752 – Schmersal

STOCK: 0.00 unidade(s)
AZM201Z-SK-T-1P2PW-A Solenoid Interlock IP66/7 “Schmersal”

Power to lock
Thermoplastic enclosure
Max. length of the sensor chain 200 m
Self-monitoring series-wiring
Coding in accordance to ISO 14119 by using RFID-Technology
3 LEDs to show operating conditions
Sensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 3 mm horizontally
Suitable for hinged and sliding guards
Intelligent diagnosis
Manual release
High holding force 2000
symmetrical construction form, assembly on 40mm profiles
OSSD safety outputs
Emergency exit / Emergency release suitable for retrofitting

eCl@ss number, version 12.0
27-27-26-03
eCl@ss number, version 11.0
27-27-26-03
eCl@ss number, version 9.0
27-27-26-03
ETIM number, version 7.0
EC002593
ETIM number, version 6.0
EC002593
Approvals – Standards
Certificates
TÜV
cULus
FCC
IC
General data
Standards
EN ISO 13849-1
EN ISO 14119
EN IEC 60947-5-3
EN IEC 61508
Coding
Universal coding
Coding level according to EN ISO 14119
Low
Working principle
RFID
Frequency band RFID
125 kHz
Transmitter output RFID, maximum
-6 dB/m
Enclosure material
Glass-fibre, reinforced thermoplastic
Gross weight
584 g
Time to readiness, maximum
4,000 ms
Duration of risk, maximum
200 ms
Reaction time, switching off safety outputs via actuator, maximum
100 ms
Reaction time, switching off safety outputs via safety inputs, maximum
0.5 ms
General data – Features
Power to lock
Yes
Solenoid interlock monitored
Yes
Manual release
Yes
Short circuit detection
Yes
Cross-circuit detection
Yes
Series-wiring
Yes
Safety functions
Yes
Integral system diagnostics, status
Yes
Number of safety contacts
2
Safety classification
Standards
EN ISO 13849-1
EN IEC 61508
Safety classification – Interlocking function
Performance Level, up to
e
Category
4
PFH value
1.90 x 10?? /h
PFD value
1.60 x 10?4
Safety Integrity Level (SIL), suitable for applications in
3
Mission time

20 Year(s)
Safety classification – Guard locking function
Performance Level, up to
d
Category
2
PFH value
1.00 x 10?8 /h
PFD value
8.90 x 10?4
Safety Integrity Level (SIL), suitable for applications in
2
Mission time
20 Year(s)
Mechanical data
Mechanical life, minimum
1,000,000 Operations
Holding force FZh in accordance with EN ISO 14119
2,000 N
Note (clamping force in accordance with EN ISO 14119)
1.000 N when used with the AZ/AZM201-B30 actuator, for indoor use.
Holding force Fmax, maximum
2,600 N
Note (clamping force, maximum)
1,300 N when used with the AZ/AZM201-B30 actuator, for indoor use.
Latching force
30 N
Actuating speed, maximum
0.2 m/s
Type of the fixing screws
2x M6
Mechanical data – Connection technique
Termination
Screw terminals
Length of sensor chain, maximum
200 m
Note (length of the sensor chain)
Cable length and cross-section change the voltage drop dependiing on the output current
Note (series-wiring)
Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD
Cable entry
1x M20
Cable section, minimum
0.25 mm²
Cable section, maximum
1.5 mm²
Note (Cable section)
All indications including the conductor ferrules.
Wire cross-section, minimum
23 AWG
Wire cross-section, maximum
15 AWG
Mechanical data – Dimensions
Length of sensor
50 mm
Width of sensor
40 mm
Height of sensor
220 mm
Ambient conditions
Ambient temperature, minimum
-25 °C
Ambient temperature, maximum
+60 °C
Storage and transport temperature, minimum
-25 °C
Storage and transport temperature, maximum
+85 °C
Relative humidity, minimum
30 %
Relative humidity, maximum
95 %
Note (Relative humidity)
non-condensing
Resistance to vibrations
10 … 150 Hz, amplitude 0.35 mm
Restistance to shock
30 g / 11 ms
Protection class
III
Ambient conditions – Insulation values
Rated insulation voltage Ui
32 VDC
Rated impulse withstand voltage Uimp
0.8 kV
Overvoltage category
III
Degree of pollution
3
Electrical data
Operating voltage
24 VDC -15 % / +10 %
Note (Power supply, general)
stabilised PELV power supply
No-load supply current I0, maximum
50 mA
Current consumption with magnet ON, average
200 mA
Current consumption with magnet ON, peak
700 mA / 100 ms
Rated operating voltage
24 VDC
Operating current
1,200 mA
Required rated short-circuit current
100 A
External wire and device fuse rating
ELEC_EXT_WIRE_DEV_FUSE_RATING4AGG
Switching frequency, maximum
1 Hz
Electrical data – Magnet control
Designation, Magnet control
IN
Switching thresholds
-3 V … 5 V (Low)
15 V … 30 V (High)
Test pulse duration, maximum
5 ms
Test pulse interval, minimum
40 ms
Classification ZVEI CB24I, Sink
C0
Classification ZVEI CB24I, Source
C1
C2
C3
Electrical data – Safety digital inputs
Designation, Safety inputs
X1 and X2
Switching thresholds
-3 V … 5 V (Low)
15 V … 30 V (High)
Current consumption at 24V
2 mA
Test pulse duration, maximum
1 ms
Test pulse interval, minimum
100 ms
Classification ZVEI CB24I, Sink
C1
Classification ZVEI CB24I, Source
C1
C2
C3
Electrical data – Safety digital outputs
Designation, Safety outputs
Y1 and Y2
Rated operating current (safety outputs)
250 mA
Design of control elements
short-circuit proof, p-type
Voltage drop Ud, maximum
2 V
Leakage current Ir, maximum
0.5 mA
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
0.25 A
Test pulse duration, maximum
0.5 ms
Test pulse interval, typical
1000 ms
Classification ZVEI CB24I, Source
C2
Classification ZVEI CB24I, Sink
C1
C2
Electrical data – Diagnostic outputs
Designation, Diagnostic outputs
OUT
Operating current
50 mA
Voltage drop Ud, maximum
4 V
Voltage, Utilisation category DC-13
24 VDC
Current, Utilisation category DC-13
0.05 A
Status indication
Note (LED switching conditions display)
Operating condition: LED green
Error / functional defect: LED red
Supply voltage UB: LED green
Scope of delivery
Scope of delivery
Actuators must be ordered separately.
Triangular key for AZM 201
Accessory
Recommendation (actuator)
AZ/AZM201-B1
AZ/AZM201-B30
Note
Note (General)
As long as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. In this case, the safety outputs are re-enabled, so that the safety guard must not be opened

REF: 103016752 Categoria: