Autosimatic - Grupo Luminag

104093 – Pepperl+Fuchs

104093 – Pepperl+Fuchs

STOCK: 0.00 unidade(s)
UC2000-30GM-IUR2-V15 Ultrasonic Sensor ULTRA 3000 “P+F”

Parameterization interface for the application-specific adjustment of the sensor setting via the service program
Analog current and voltage output
Synchronization options
Adjustable acoustic power and sensitivity
Temperature compensation

Single head system
General specifications
Sensing range 80 … 2000 mm
Adjustment range 120 … 2000 mm
Dead band 0 … 80 mm
Standard target plate 100 mm x 100 mm
Transducer frequency approx. 180 kHz
Response delay 65 ms minimum
195 ms factory setting
Indicators/operating means
LED green solid: Power-on
flashing: Standby mode or program function object detected
LED yellow 1 solid: object in evaluation range
flashing: program function
LED yellow 2 solid: object in detection range
flashing: program function
LED red solid: temperature/program plug not connected
flashing: fault or program function object not detected
Temperature/TEACH-IN connector Temperature compensation , Evaluation range programming , output function setting
Electrical specifications
Operating voltage 10 … 30 V DC , ripple 10 %SS
Power consumption = 900 mW
Time delay before availability = 500 ms
Interface
Interface type RS 232, 9600 Bit/s , no parity, 8 data bits, 1 stop bit
Input/Output
Synchronization bi-directional
0 level -UB…+1 V
1 level: +4 V…+UB
input impedance: > 12 KOhm
synchronization pulse: = 100 µs, synchronization interpulse period: = 2 ms
Synchronization frequency
Common mode operation max. 30 Hz
Multiplex operation = 30 Hz / n , n = number of sensors , n = 5
Output
Output type 1 current output 4 … 20 mA
1 voltage output 0 … 10 V
Resolution evaluation range [mm]/4000, but = 0.35 mm
Deviation of the characteristic curve = 0.2 % of full-scale value
Repeat accuracy = 0.1 % of full-scale value
Load impedance current output: = 500 Ohm
voltage output: = 1000 Ohm
Temperature influence = 2 % from full-scale value (with temperature compensation)
= 0.2 %/K (without temperature compensation)
Compliance with standards and directives
Standard conformity
Standards EN IEC 60947-5-2:2020
IEC 60947-5-2:2019
EN 60947-5-7:2003
IEC 60947-5-7:2003
Approvals and certificates
UL approval cULus Listed, General Purpose
CCC approval CCC approval / marking not required for products rated =36 V
Ambient conditions
Ambient temperature -25 … 70 °C (-13 … 158 °F)
Storage temperature -40 … 85 °C (-40 … 185 °F)
Mechanical specifications
Connection type Connector plug M12 x 1 , 5-pin
Housing diameter 30 mm
Degree of protection IP65
Material
Housing stainless steel (1.4305 / AISI 303)
PBT plastic parts
Transducer epoxy resin/hollow glass sphere mixture; polyurethane foam
Mass 170 g
Factory settings
Output evaluation limit A1: 200 mm
evaluation limit A2: 2000 mm
rising ramp
Classifications
System Classcode
ECLASS 11.0 27272803
ECLASS 10.0.1 27272803
ECLASS 9.0 27272803
ECLASS 8.0 27272803
ECLASS 5.1 27272803
ETIM 8.0 EC001849
ETIM 7.0 EC001849
ETIM 6.0 EC001849
ETIM 5.0 EC001849
UNSPSC 12.1 41111960