S31A-7011CA Safety Laser Scanner Cold Store Indoor “Sick”

Protective field range 7 m
Warning field range 49 m (20 m at 20 % reflectivity)
Distance measuring range 49 m
Number of simultaneously monitored protective fields = 4 1)
Type of field set Triple field sets, dual field sets
Number of field sets 4
Number of fields 12
Number of monitoring cases 4
Scanning angle 180°
Resolution (can be configured) 30 mm, 40 mm, 50 mm, 70 mm, 150 mm
Angular resolution 0.5°, 0.25°, depending on range and resolution
Response time 120 ms 2)
Protective field supplement 100 mm
Number of multiple samplings 2 … 16, configurable
Delay of automatic reset 2 s … 60 s, configurable
1) If several protective fields are monitored simultaneously, the shut-off signals must be connected to safe outputs on a Flexi Soft safety controller or routed via a safe EFI gateway.
2) Depending on basic response time and multiple sampling
Type Type 3 (IEC 61496)
Safety integrity level SIL2 (IEC 61508)
Category Category 3 (EN ISO 13849)
Performance level PL d (EN ISO 13849)
PFHD (mean probability of a dangerous failure per hour) 8.0 x 10-8
TM (mission time) 20 years (EN ISO 13849)
Safe state in the event of a fault At least one OSSD is in the OFF state
Connection type System plug
Inputs
Static control inputs 2
Static control inputs with EFI 5 1)
Outputs
OSSD pairs 1
Application diagnostic outputs 2 2)
Configuration method PC with CDS (Configuration and Diagnostic Software)
Configuration and diagnostics interface RS-232
Transmission rate 9.6 kBaud, 19.2 kBaud, 38.4 kBaud
Safe SICK device communication via EFI
Transmission rate = 500 kBaud
Length of cable = 50 m
Conductor cross section 0.34 mm²
1) In combination with an EFI device (Flexi Soft or EFI gateway) five static control inputs are available. Otherwise two.
2) Freely programmable, e.g. warning field, contamination, reset required
Protection class II (EN 50178)
Supply voltage Vs
Scanner 24 V DC (17.5 V DC … 28.8 V DC)
Heating 24 V DC (16.8 V DC … 28.8 V DC)
Power consumption
Scanner = 0.8 A 1)
= 2.3 A 2)
Heating = 6 A, cyclical
Outputs
Output signal switching devices (OSSDs) 2 x 500 mA
Application diagnostic outputs 2 x 100 mA 3)
1) At 24 V DC without output load.
2) At 24 V DC including maximum output load.
3) Freely programmable, e.g. warning field, contamination, reset required
Dimensions (W x H x D) 351 mm x 265 mm x 221 mm
Weight 9 kg
Material
Back panel, plug Aluminum die cast
Cover Polyurethane
Housing color RAL 1021 (yellow)
Front screen material Polycarbonate
Front screen surface finish Outside with scratch-resistant coating
Enclosure rating
IP65 (EN 60529)
IP67 (EN 60529)
Ambient operating temperature –30 °C … +50 °C
Storage temperature –30 °C … +50 °C
Vibration resistance IEC 60068-2-6, IEC 60068-2-64, IEC 60721-3-5, IEC TR 60721-4-5, IEC 61496-3
Class 5M1 (IEC 60721-3-5)
Shock resistance IEC 60068-2-27, IEC 60721-3-5, IEC TR 60721-4-5, IEC 61496-3
Class 5M1 (IEC 60721-3-5)
Continuous shock 50 m/s², 11 ms
100 m/s², 16 ms
Type of light Pulsed laser diode
Wave length 905 nm
Detectable remission factor 1.8 % … > 1,000 %, reflectors
Laser class 1 (21 CFR 1040.10 and 1040.11, IEC 60825-1)
eCl@ss 5.0 27272705
eCl@ss 5.1.4 27272705
eCl@ss 6.0 27272705
eCl@ss 6.2 27272705
eCl@ss 7.0 27272705
eCl@ss 8.0 27272705
eCl@ss 8.1 27272705
eCl@ss 9.0 27272705
eCl@ss 10.0 27272705
eCl@ss 11.0 27272705
eCl@ss 12.0 27272705
ETIM 5.0 EC002550
ETIM 6.0 EC002550
ETIM 7.0 EC002550
ETIM 8.0 EC002550
UNSPSC 16.0901 39121528

REF: 1041648 Categoria: