Autosimatic - Grupo Luminag

1045654 – Sick

1045654 – Sick

STOCK: 0.00 unidade(s)
S30A-7111CP Safety Laser Scanner Profinet IO 190° “Sick”

1 045 654
Usage S3000 PROFINET IO does not have any local inputs or outputs and is only operated in a network with corresponding controller.
Model Sensor without system plug
Application Indoor
Protective field range 7 m
Warning field range 49 m (20 m at 20 % reflectivity)
Distance measuring range 49 m
Number of simultaneously monitored protective fields 2
Type of field set Dual field sets
Number of field sets 4
Number of fields 8
Number of monitoring cases 4
Resolution (can be configured) 30 mm, 40 mm, 50 mm, 70 mm, 150 mm
Angular resolution 0.5°, 0.25°, depending on range and resolution
Response time 60 ms 1)
Protective field supplement 100 mm
Number of multiple samplings 2 … 16, configurable
Delay of automatic reset 120 ms … 4,920 ms, configurable
1) Depending on basic response time and multiple sampling
Type Type 3 (IEC 61496)
Safety integrity level SIL2 (IEC 61508)
Category Category 3 (EN ISO 13849)
Performance level PL d (EN ISO 13849)
PFHD (mean probability of a dangerous failure per hour) 8.0 x 10-8
TM (mission time) 20 years (EN ISO 13849)
Safe state in the event of a fault The safety-related data is logic 0
Restart interlock Yes
Multiple sampling Yes
Monitoring case switching Yes
Simultaneous monitoring Yes
Static protective field switching Yes
Contour as a reference Yes
Integrated configuration memory Yes
Measured data output Via RS-422
Connection type
Bus connection Copper conductor (2 female connectors for RJ-45 push-pull plug)
Supply connection System plug with or without connecting cable
Configuration and diagnostics interface RS-232
Transmission rate 9.6 kBaud, 19.2 kBaud, 38.4 kBaud
Fieldbus, industrial network PROFINET PROFIsafe
Type of fieldbus integration Integrated in the device
Device properties PROFINET IO device with 2-port real-time switch according to PROFINET specification V2.2
PROFIsafe profile with 6-octet input and 6-octet output according to IEC 61784-3-3 V2.4
Cycle time 4, 8, 16, 32 ms, etc.
GSDML according to GSDML specification V2.25
Switch properties Filtering Data Base according to IEEE 802.1D
6 prioritization levels for IEEE 802.1Q – Network prioritization
64 KB SRAM memory for caching telegrams, managed in 768-byte segments
Resource prioritization for network control and RTC2/3 frames
Telegram extension based on “Cut-through”
Port status (Disabled, Blocking, Forwarding)
Support for non-real-time and real-time data transfer
Port properties Auto-negotiation
Auto-crossover (MDIX)
Auto-polarity
100Base-TX
Conformance Conformance Class B
Topology support SNMP, MIB-2, LLDP according to IEEE 802.1AB
MRP client support
Diagnostics Application-related manufacturer-specific channel diagnostics and channel diagnostics for the PROFIsafe profile, individually switchable
Report system errors
Cable diagnostics
Neighborhood alerts
Support for port statistics
I&M support from I&M0 to I&M4
Interfaces TCP port 9000 and UDP port 30718
RS-232
Functions that are not supported Multicast communication
Supervisor AR
MAC-pause mechanism in full duplex
Back-pressure in half duplex
Static learning
Broadcast Storm Control
Protection class III (VDE 0106, EN 60950)
Supply voltage Vs 24 V DC (16.8 V DC … 28.8 V DC)
Power consumption = 0.8 A 1)
1) At 24 V DC without output load
Dimensions (W x H x D) 155 mm x 185 mm x 160 mm
Weight 3.3 kg
Housing material Aluminum die cast
Housing color RAL 1021 (yellow)
Front screen material Polycarbonate
Front screen surface finish Outside with scratch-resistant coating
Enclosure rating IP65 (EN 60529)
Ambient operating temperature –10 °C … +50 °C
Storage temperature –25 °C … +50 °C
Vibration resistance IEC 60068-2-6, IEC 60068-2-64, IEC 60721-3-5, IEC TR 60721-4-5, IEC 61496-3
Class 5M1 (IEC 60721-3-5)
Shock resistance IEC 60068-2-27, IEC 60721-3-5, IEC TR 60721-4-5, IEC 61496-3
Class 5M1 (IEC 60721-3-5)
Continuous shock 50 m/s², 11 ms
100 m/s², 16 ms
Type of light Pulsed laser diode
Wave length 905 nm
Detectable remission factor 1.8 % … > 1,000 %, reflectors
Laser class 1 (21 CFR 1040.10 and 1040.11, IEC 60825-1)
eCl@ss 5.0 27272705
eCl@ss 5.1.4 27272705
eCl@ss 6.0 27272705
eCl@ss 6.2 27272705
eCl@ss 7.0 27272705
eCl@ss 8.0 27272705
eCl@ss 8.1 27272705
eCl@ss 9.0 27272705
eCl@ss 10.0 27272705
eCl@ss 11.0 27272705
eCl@ss 12.0 27272705
ETIM 5.0 EC002550
ETIM 6.0 EC002550
ETIM 7.0 EC002550
ETIM 8.0 EC002550
UNSPSC 16.0901 39121528

REF: 1045654 Categoria: