HL18L-P4A5BA Hybrid Photoelectric SureSense M18 “Sick”

Sensor/ detection principle Photoelectric retro-reflective sensor, Dual lens
Dimensions (W x H x D) 16.2 mm x 48.5 mm x 31.8 mm
Housing design (light emission) Hybrid
Thread diameter (housing) M18
Mounting system type M18, nose / side (24.1 … 25.4 mm)
Housing color Blue
Sensing range max. 0.1 m … 12 m 1)
Sensing range 0.1 m … 10 m 1)
Type of light Visible red light
Light source Laser 2) 3)
Light spot size (distance) 2 mm (2 m)
Wave length 655 nm
Laser class I
Adjustment
Potentiometer, right None
Potentiometer, left None
Special applications Detecting small objects
Special features Signal strength light bar
1) Reflector PL80A.
2) Average service life: 50,000 h at TU = +25 °C.
3) CLASS 1 LASER PRODUCT EN60825-1:2014, IEC60825-1:2014, Maximum pulse power < 2,5 mW, Pulse length: 4 µs, Wavelength: 650 ... 670 nm, Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007 Supply voltage 10 V DC ... 30 V DC Ripple < 5 Vpp 1) Current consumption = 20 mA 2) Switching output PNP Output function Complementary Switching mode Light/dark switching Switching output detail Switching output Q1 PNP, Light switching Switching output Q2 PNP, Dark switching Output current Imax. = 100 mA Response time = 0.5 ms 3) Switching frequency 1,000 Hz 4) Connection type Male connector M12, 4-pin Circuit protection A 5) B 6) D 7) Protection class III Weight 18 g Polarisation filter ? Housing material Plastic, VISTAL® Optics material Plastic, PMMA Enclosure rating IP67 IP69K Items supplied Mounting nut (1x), M18, plastic, black, flat Electromagnetic compatibility (EMC) EN 60947-5-2 (The sensor complies with the Radio Safety Requirements (EMC) for the industrial sector (Radio Safety Class A). It may cause radio interference if used in a residential area.) Ambient operating temperature –30 °C ... +55 °C 8) Ambient temperature, storage –40 °C ... +70 °C UL File No. E189383 1) May not exceed or fall below Uv tolerances. 2) Without signal strength light bar and load. 3) Signal transit time with resistive load. 4) With light/dark ratio 1:1. 5) A = VS connections reverse-polarity protected. 6) B = inputs and output reverse-polarity protected. 7) D = outputs overcurrent and short-circuit protected. 8) Below Ta = –10 °C, sensor must be turned on at Ta > –10 °C. Sensor cannot be turned on below Ta= –10 °C

MTTFD 417.2 years
DCavg 0 %

ECl@ss 5.0 27270902
ECl@ss 5.1.4 27270902
ECl@ss 6.0 27270902
ECl@ss 6.2 27270902
ECl@ss 7.0 27270902
ECl@ss 8.0 27270902
ECl@ss 8.1 27270902
ECl@ss 9.0 27270902
ECl@ss 10.0 27270902
ECl@ss 11.0 27270902
ECl@ss 12.0 27270902
ETIM 5.0 EC002717
ETIM 6.0 EC002717
ETIM 7.0 EC002717
ETIM 8.0 EC002717
UNSPSC 16.0901 39121528

Connection type Male connector M12, 4-pin
Pin assignment
BN 1 + (L+)
WH 2 Q2
BU 3 – (M)
BK 4 Q1

REF: 1071025 Categoria: