Autosimatic - Grupo Luminag

1080321 – Sick

1080321 – Sick

STOCK: 0.00 unidade(s)
MLP1-SMMF0AC RFID Safety switches: MLP1 Power to lock “Sick”

Coding Universally coded
Locking force Fmax 550 N (GS-ET-19)
Locking force FZh 500 N (GS-ET-19)
Retaining force 25 N
Offset tolerance = 5 mm
Safe switch off distance Sar 45 mm
Safety integrity level SIL3 (IEC 61508)
Category Category 4 (EN ISO 13849)
Performance level PL e (EN ISO 13849) 1)
PFHD (mean probability of a dangerous failure per hour) 15 * 10-9 2)
TM (mission time) 20 years (EN ISO 13849)
Type Type 4 (EN ISO 14119)
Actuator coding level Low coding level (EN ISO 14119)
Safe state in the event of a fault At least one safety-related semiconductor output (OSSD) is in the OFF state.
1)
In a safe series connection, the performance level for the safe series connection as a whole depends on the number and type of devices in the safe series connection. PL e is only possible in safe series connections with a maximum of 6 devices.
2)
At 40 °C and 1000 m above sea level
Switching behavior of the OSSDs Actuator monitoring
Safe series connection
With T-connector (without diagnostics)
With Flexi Loop (with diagnostics)
Connection type Cable with plug M12, 8-pin
Length of cable 150 mm
Long connecting cable = 100 m
Cable diameter 5.5 mm
Conductor cross section 0.12 mm²
Bend radius (with fixed installation) > 8 x cable diameter
Bend radius (with moving cable) > 12 x cable diameter
Cable material PVC
Conductor material Copper
Coupling nut material Zinc die-cast, nickel-plated
Display elements LEDs
Protection class III (IEC 61140)
Contamination rating 3 (EN 60947-1)
Classification according to cULus Class 2
Usage category DC-13 (IEC 60947-5-1)
Rated insulation voltage Ui 32 V
Rated impulse withstand voltage Uimp 1,500 V
Supply voltage UV when an individual safety switch is connected
Sensor 24 V DC (19.2 V DC … 28.8 V DC)
Magnet 24 V DC (19.2 V DC … 28.8 V DC)
Supply voltage UV when a cascade is connected
Sensor 24 V DC (22.8 V DC … 28.8 V DC)
Magnet 24 V DC (21.6 V DC … 28.8 V DC)
Power consumption
Locking active 350 mA
Locking deactivated 50 mA
Switching frequency = 0.5 Hz
Type of output Self-monitoring semiconductor outputs (OSSDs)
Output current (OSSDs) = 100 mA
Diagnostic output = 25 mA, short-circuit protected
Cable capacitance 400 nF (for OUT A and OUT B)
Response time 50 ms 1)
Release time 100 ms 1)
Risk time 100 ms 1)
Switch-on time 2.5 s
Locking principle Power to lock
1)
In a cascade, the value is multiplied by the number of safety switches in the cascade
Weight
Switches (spare parts) 510 g
Actuator 210 g
Material
Sensor housing Anodized aluminum
Actuator housing Fiber-glass-reinforced PVC
Anchor plate Nickel-plated steel
Dimensions (W x H x D)
Switches (spare parts) 120 mm x 60 mm x 38.5 mm
Actuator 120 mm x 60 mm x 20.5 mm
Offset tolerance
Vertical = 5 mm
Horizontal = 5 mm
Aperture angle = 3°
Enclosure rating IP67 (EN 60529)
Ambient operating temperature –20 °C … +55 °C
Storage temperature –25 °C … +70 °C
Relative humidity 50 %, at 70 °C (IEC 60947-5-2)
Vibration resistance 10 Hz … 55 Hz, 1 mm (IEC 60068-2-6)
Shock resistance 30 g, 11 ms (EN 60068-2-27)
EMC
EN IEC 61326-3-1
EN IEC 60947-5-2
EN IEC 60947-5-3

REF: 1080321 Categoria: