150-F625NBA – Allen-Bradley
STOCK: 0.00 unidade(s)
SMC Flex Smart Motor Controller 625A “Allen-Bradley”
EAN: 10662074789136
With display Yes
Voltage type for actuating AC
Rated operating voltage Ue 200 V
Rated control supply voltage at AC 50 Hz 230 V
Rated control supply voltage at AC 60 Hz 230 V
Overload current for line connected devices 208 A
Overload current for delta connected devices 283 A
Controller type Soft starter
Control options None
Trip classes 10, 15, 20 and 30
Trip current rating 117% of motor FLC
Heatsink fan rating 150VA @ 110/120V AC or 220/240V AC
DV/DT protection RC snubber network for power circuit
Repetitive peak inverse voltage rating 1400V per UL/CSA/NEMA for power circuit
Operating frequency 50/60 Hz for power circuit
Line connected motor power, max 800 Hp @ 600V AC, 60 Hz, 3-phase
Delta connected motor power, max 900 Hp @ 575V AC, 60 Hz, 3-phase
Rated impulse voltage 6000V per IEC for power circuit
Dielectric withstand 2500V per IEC for power circuit
Line connected motor current 208…625 A @ 600/Y/690V AC, 3-phase
Delta connected motor current 283…850 A @ 500/575V AC, 3-phase
Ampere tested european style, max 6, 6URD33xxx1400 @ 690V for maximum FLC
Ampere tested north american style, max A070URD33xxx1400 @ 690V for maximum FLC
Transient protection Metal oxide varistors: 220 Joules (optional) for power circuit
Insulation voltage Rated 500V per IEC for power circuit
Rated operational voltage 200…480V AC (-15%, +10%) per UL/CSA/NEMA for power circuit
Input OFF-state current <10 mA AC, <3 mA DC for control circuit @ input OFF-state voltage
Short-circuit protection device list Standard fuse, circuit breaker and high capacity time delay class CC/J/L
Number of contacts 1 for auxiliary contacts
High capacity available fault current, max 74 kA @ 600V, maximum current 1600 A time delay Class J or Class L fuse for line connected motors
Type of current AC for auxiliary contacts
Conventional thermal current (Ith) AC/DC: 5 A for auxiliary contacts
Type of control circuit Electromagnetic relay for auxiliary contacts
Type of contacts Programmable NO/NC for auxiliary contacts
Utilization category MG 1 per UL/CSA/NEMA for power circuit
Standard controller feature Status indication: stopped, starting, stopping, at speed, alarm and fault
Standard available fault current, max 70 kA @ 690V for maximum FLC
Optional controller feature SMB smart motor braking control: provides motor braking without additional equipment for applications that require the motor to stop quickly, braking current is adjustable from 0...400% of the motor’s full-load current rating
Integrated motor overload protection Yes
Short circuit protection device performance (SCPD) type Type 1
Number of sensors, max 6 for PTC input ratings
Voltage at PTC terminals (RPTC = open), max 30V for PTC input ratings
Voltage at PTC terminals (RPTC = 4 kO), max <7.5 for PTC input ratings
Transformer rating control module 751 VA (recommended 800 VA)
Response time 800 ms for PTC input ratings
Cold resistance of PTC sensor chain, max 1500 Ohm for PTC input ratings
Tachometer input 0...5V DC, 4.5V DC = 100% Speed
Short circuit trip resistance 25 Ohm ± 10 Ohm for PTC input ratings
Response resistance 3400 Ohm ± 150 Ohm for PTC input ratings
Reset resistance 1600 Ohm ± 100 Ohm for PTC input ratings
Input OFF-state voltage, max 50V AC, 10V DC/12V AC for control circuit
Input ON-state voltage, min 85V AC, 19.2V DC/20.4V AC for control circuit
Rated operational current 3 A @ 120V AC, 1.5 A @ 240V AC for auxiliary contacts
Input ON-state current 20 mA @ 120V AC/40mA @ 240V AC, 7.6 mA @ 24V AC/DC for control circuit
Contact type auxiliary contacts 19/20 (Aux #1), 29/30 (Aux #2), 31/32 (Aux #3) and 33/34 (Aux #4)
Environmental
Steady state heat dissipation with control and fan power 446 W
Storage and transportation temperature -20 °C
Humidity 5...95% (noncondensing)
Operating temperature Open: -5 to 50 °C (23 to 122 °F)
Protection against electrical shock IP00 (open device) per IEC for power circuit
EMC emission levels Radiated emission: Class A
EMC immunity levels Surge transient: per EN/IEC 60947-4-2
Altitude 2000 m
Pollution degree 2
Mechanical
Weight 179 kg
Shock Operational: 4 G
Width 596.9 mm (23.50 inch)
Depth 346.2 mm (13.63 inch)
Height 1041.1 mm (41 inch)
Power pole construction Heatsink hockey puck thyristor modular design
Vibration Operational: 1.0 G peak, 0.15 mm (0.006 inch) displacement
Make 3600VA for auxiliary contacts
Break 360VA for auxiliary contacts
Internal bypass Yes
Function Single direction
Power terminal markings NEMA, CENELEC EN50 012
Control terminals Clamping yoke connection, M3 screw clamp
Construction
Line/load side power terminals Two 13.5 mm (0.53 inch) diameter holes per power pole
Number of poles 3
Enclosure Open type
Control modules construction Thermoset and thermoplastic moldings
Metal parts construction Plated brass, copper or painted steel
Documentation
RESOURCE PUBLICATION NUMBER
Technical Data 150-TD009
User Manual 150-UM007
Find more technical documentation for this product in the Technical Documentation Center.
Certifications
Eurasion Economic Community Australian RCM China CCC
Eurasion Economic Community
Australian RCM
China CCC
This product was certified with the above certifications as of 2023-11-28. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries