MLV11-54-Ex/40b/112 Retroreflective Sensor ATEX NAMUR “P+F”

approval for zone 1 (Gas)
Intrinsically safe, Ex op is ia IIC T6 Gb
Glare protected with polarization filter
Adjustable sensitivity

retroreflective sensor, small housing design, 3 m detection range, red light, light/dark on, DC version, NAMUR output, M12 plug

Effective detection range 0 … 3 m
Reflector distance 300 … 3000 mm
Threshold detection range 3 m
Reference target H85 reflector
Light source LED
Light type modulated visible red light , 660 nm
Polarization filter yes
Ambient light limit = 10000 Lux sun light
= 7500 Lux halogen light
Functional safety related parameters
MTTFd 1319 a
Mission Time (TM) 20 a
Diagnostic Coverage (DC) 0 %
Indicators/operating means
Function indicator LED yellow: switching state
Control elements sensitivity adjustment
Electrical specifications
Operating voltage 6 … 15.5 V DC (Ri approx. 0 Ohm)
Ripple 5 %
Power consumption max. 64 mW
Time delay before availability 20 ms
Output
Switching type light/dark on, programmable
Signal output 1 NAMUR output NC/NO programmable
Switching voltage 8 V DC (Ri approx. 1 kO)
Switching frequency = 100 Hz
Current consumption
Reference target detected connection 1, 2: = 2.2 mA
connection 1, 4: = 1 mA
Reference target not detected connection 1, 2: = 1 mA
connection 1, 4: = 2.2 mA
Response time 5 ms
Conformity
Product standard EN 60947-5-2
Approvals and certificates
CCC approval CCC approval / marking not required for products rated =36 V
Ambient conditions
Ambient temperature -25 … 70 °C (-13 … 158 °F)
Storage temperature -40 … 80 °C (-40 … 176 °F)
Mechanical specifications
Housing width 18 mm
Housing height 50 mm
Housing depth 45 mm
Degree of protection IP67
Connection V1 connector (M12 x 1), 4-pin, rotatable through 90°
Material
Housing PBT
Optical face scratch resistant plastic lens
Mass 60 g
ATEX G
EC-Type Examination Certificate PTB 99 ATEX 2036X
Applicant Pepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany
CE marking CE0102
ATEX marking Zone 1: Ex-Hexagon II 2G Ex ia op is IIC T6…T1 Gb
Directive conformity 2014/34/EU
Standards EN 60079-0:2012+A11:2013
EN 60079-11:2012
EN 60079-28:2007
Effective internal capacitance Ci max. 120 nF
Effective internal inductance Li negligibly small
General The apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The EU-type examination certificate has to be observed.
Ambient temperature The temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate.
Installation, commissioning The associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety.
Maintenance No modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible.
Special conditions
Protection from mechanical danger When used in the temperature range below -20 °C the sensor should be protected from knocks by the provision of an additional housing.
Degree of protection required when installing connecting components IP20 according to IEC 60529:2001
Other conditions Refer to the relevant EC type examination certificate to see the relationship between the connected circuit type, the maximum permitted ambient temperature and the temperature class as well as effective inner reactances.
IECEx G
Certificate number IECEx PTB 12.0061 X
Applicant Pepperl+Fuchs GmbH, Lilienthalstrasse 200, 68307 Mannheim, Germany
IECEx marking Zone 1: Ex-Hexagon II 2G Ex ia op is IIC T6…T1 Gb
Standards IEC 60079-0:2011 IEC 60079-11:2011 IEC 60079-28:2006
Effective internal capacitance Ci max. 120 nF
Effective internal inductance Li negligibly small
General The apparatus must be operated in accordance with the data provided in the data sheet and this operating instruction. In particular, the maximum rated voltage and the temperature range must be adhered to. The special conditions must be adhered to! The IECEx certificate must be observed.
Ambient temperature The temperature ranges, according to temperature class, are given in the EC-Type Examination Certificate.
Installation, commissioning The associated apparatus must, as a minimum, fulfill the requirements for degree of protection ia and for Groups II or III, as appropriate for the operating conditions. Due to the possible risk of ignition that can occur as a result of faults and/or transient currents in the equipotential bonding system, galvanic isolation in the supply and signal current circuit is preferred. Associated apparatus without galvanic isolation may only be used if the appropriate requirements as set out in IEC 60079-14 are met. The intrinsic safety is only assured in connection with an appropriate related apparatus and according to the proof of intrinsic safety.
Maintenance No modifications must be undertaken on apparatus, which is operated in hazardous areas. Repairs to such apparatus are not permissible.
Special conditions
Protection from mechanical danger When used in the temperature range below -20 °C the sensor should be protected from knocks by the provision of an additional housing.
Degree of protection required when installing connecting components IP20 according to IEC 60529:2001
Other conditions Refer to the relevant EC type examination certificate to see the relationship between the connected circuit type, the maximum permitted ambient temperature and the temperature class as well as effective inner reactances.
Classifications