Autosimatic - Grupo Luminag

547054 – Pepperl+Fuchs

547054 – Pepperl+Fuchs

STOCK: 0.00 unidade(s)
SK-PC-D2-UU1-10-HS Div.2 Zone 2 Ex-Rated Barrier “P+F”
1- or 2-channel Division 2 non-incendive barrier
Div 2/Zone 2 mountable
USB or PS2 interface for Ex-rated keyboard or mouse
Rated voltage 9 … 30 VDC (Um = 30 V SELV)
Input current 120 mA nominal
500 mA max
Indicators/operating means
LED ON power – keyboard
power – Mouse
Interface
Interface type USB 1.1 or PS2
Output
Output rated operating current 89 mA
Output voltage 4.8 VDC
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
RoHS
Directive 2011/65/EU (RoHS) EN 50581:2012-09
Conformity
Degree of protection IEC 60529
Protection against electrical shock IEC 61140
Ambient conditions
Ambient temperature -40 … 60 °C (-40 … 140 °F)
Relative humidity 0 … 95% (noncondensing)
Vibration resistance 5 G, 58 … 150 Hz
Impact resistance 15 g, 11 ms
Mechanical specifications
Connection type Terminal Block
Degree of protection IP20
Connection Supply: terminals 13+, 14-
Input: terminals 9+, 10-; 11+, 12-
Output: terminals 1+, 2+, 3-, 4-; 5+, 6+, 7-, 8- (field terminal)
Ground: terminals 15, 16
Mass 120 g
Dimensions 99 mm x 85 mm x 22.5 mm
Cable length 4.6 m (15′): barrier to keyboard/mouse
4.6 m (15′): host pc to keyboard/mouse
6.1 m (20′): total length, host PC to keyboard/mouse
Data for application in connection with hazardous areas
EU-type examination certificate DEMKO 14ATEX1269806X
Marking Ex-Hexagon II 3 G Ex nA [ic] IIC T6 Gc
Ex-Hexagon II 3 G Ex nA [ic IIIB] IIC T6 Gc
Directive conformity
Directive 2014/34/EU EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010
International approvals
UL approval cULus (E106378)
Control drawing 116-0337
Approved for Mountable in
Class I, Division 2, Groups A, B, C, D
Providing non-incendive field wiring at field terminals to
Class I, Division 2, Groups A, B, C, D
Class II, Division 2, Groups F, G
Class III, Division 2
Temperature Class T6
Mountable in
Class I, Zone 2
Providing intrinsic safety wiring at field terminals for
Class I, Zone 2, Group IIC and Group IIIB hazardous locations
USL:
Class I, Zone 2 AEx nA [ic] IIC T6 Gc
Class I, Zone 2 AEx nA [ic IIIB] IIC T6 Gc
CNL:
Class I, Zone 2, Ex nA [ic] IIC T6 Gc X
Class I, Zone 2, Ex nA [ic IIIB] IIC T6 Gc X
IECEx approval IECEx UL 14.0017X
Approved for Ex nA [ic] IIC T6 Gc
Ex nA [ic IIIB] IIC T6 Gc
Standards IEC 60079-0:2011 (6th edition)
IEC 60079-11:2011 (6th edition)
IEC 60079-15:2010 (4th edition)
Classifications
System Classcode
ECLASS 11.0 19200301
ECLASS 10.0.1 19200301
ECLASS 9.0 19200301
ECLASS 8.0 19200301
ECLASS 5.1 27242392
ETIM 8.0 EC001692
ETIM 7.0 EC001692
ETIM 6.0 EC001692
ETIM 5.0 EC001692
UNSPSC 12.1 43211706
ATEX Certificate DEMKO 14 ATEX 1269806X ALL PDF 522 KB
Canada UL cUL E106378 cUL (QUZW7) ALL LINK —
IECEx Certificate of Conformity IECEx UL 14.0017X ALL LINK —
UL Hazardous Location E106378 (QUZW, QUZW7, QVAG, QVAG7) ALL PDF 584 KB
USA UL E106378 UL (QUZW) ALL LINK —
Control Drawings
Control drawing UL / Control drawing UL ALL PDF 91 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F) DOC-B055C ALL PDF 47 KB

REF: 547054 Categoria: