6012147 – Sick
STOCK: 0.00 unidade(s)
T4000-1RBA01 Non-Contact Safety Switch RFID “Sick”
6 012 147
Category Category 3 (EN ISO 13849)
Performance level PL e (EN ISO 13849)
PFHD (mean probability of a dangerous failure per hour)
4.3 x 10-8 1)
8.8 x 10-8 2)
TM (mission time)
20 years (EN ISO 13849) 1)
8 years (EN ISO 13849) 2)
Type Type 4 (EN ISO 14119)
Actuator coding level High coding level (EN ISO 14119)
Classification in compliance with IEC/EN 60947-5-3 PDF-M
1) With < 34.600 switching cycles p.a.
2) With < 90.000 switching cycles p.a.
Protection class III (EN 50178)
Contamination rating 2
Classification according to cULus Class 2
Note on supply voltage US Operation with UL-class 2 power supply only
External fuse At supply voltage Vs 0.25 A ... 8 A
Switching voltage 60 V DC / 30 V AC
Usage category AC-12/DC-12, AC-14/DC-13 (EN 60947-5-2)
Rated operating current (voltage)
0.3 A (60 V AC) 50 Hz
6 A (30 V AC) 50 Hz
0.3 A (60 V DC)
6 A (30 V DC)
2 A (30 V AC) 50 Hz
3 A (24 V DC)
Rated insulation voltage Ui 63 V
Rated impulse withstand voltage Uimp 1,500 V AC
Supply voltage Vs 24 V DC (21 V DC ... 27 V DC)
Short-circuit protection 6 A gG
Type of output Relays
Switching voltage = 0.1 V DC
Response time = 180 ms
Switch-on time = 3 s 1)
Number of application diagnostic outputs 1 semiconductor, p-switching
Number of safe outputs (N/O) 2
1) When the operating voltage is switched on, the relay outputs are electrically isolated during the initialisation period, and the door alarm contact set to LOW
Design Rectangular
Dimensions (W x H x D) 22.5 mm x 114 mm x 99 mm
Weight 0.327 kg
Housing material Plastic PA6.6
Mechanical life 10 x 106 switching cycles