Device type Photoelectric sensors
Sensor/ detection principle Photoelectric proximity sensor, Background suppression
Dimensions (W x H x D) 17.4 mm x 45.6 mm x 34.7 mm
Housing design (light emission) Rectangular
Sensing range max. 200 mm … 3,000 mm 1)
Sensing range
200 mm … 3,000 mm 2)
1)
Type of light Visible red light
Light source Laser 3)
Light spot size (distance) Ø 12 mm (3,000 mm)
Wave length 658 nm
Laser class 1 (IEC 60825-1 / CDRH 21 CFR 1040.10 & 1040.11)
Adjustment
Single teach-in button (4 x)
Display
1) Object with 6 … 90 % remission (based on standard white to DIN 5033).
2) Adjustable.
3) Average service life: 100,000 h at TU = +25 °C
Supply voltage 10 V DC … 30 V DC 1)
Ripple < 5 Vpp 2)
Current consumption 75 mA 3)
Switching output
PNP 4)
NPN 5)
Number of switching outputs 3 (Q1, Q2, Q3) 4)
Switching mode Light/dark switching 4)
Switching mode selector Selectable via menu
Output current Imax. = 100 mA
Response time
0.6 ms 6)
1 ms 7)
3.4 ms 8)
13 ms
51.4 ms
Switching frequency
833 Hz 9)
500 Hz 7)
147 Hz 8)
38 Hz
10 Hz
Time functions
Without time delay
Off delay
On delay
One shot
Delay time Programmable, 0 ms ... 999 ms
Analog output -
Input MFin = multifunctional input programmable 10)
Connection type Cable with plug M12, 5-pin, 0.3 m 11)
Cable material PVC
Circuit protection
A 12)
B 13)
C 14)
Protection class III
Weight 45 g
Housing material Plastic, ABS
Optics material Plastic, PMMA
Enclosure rating IP67
Items supplied BEF-W190 mounting bracket
Ambient operating temperature –30 °C ... +50 °C 15)
Ambient temperature, storage –40 °C ... +70 °C
Warm-up time < 5 min 16)
Initialization time < 300 ms
1) Limit values. Operated in short-circuit protected network: max. 8 A.
2) May not exceed or fall below Uv tolerances.
3) Without load. At VS = 24 V.
4) Q1, Q2, Q3 = 3 switching thresholds, light/dark switching selectable via light/dark selector.
5) PNP/NPN switchable.
6) Signal transit time with resistive load.
7) Can be set via a mean value filter (AVG1, AVG4, AVG16, AVG64, AVG256).
8) Depending on distance to object, distance to background and selected switching threshold.
9) With light/dark ratio 1:1.
10) External teach-in via cable, laser shutdown.
11) Do not bend below 0 °C.
12) A = VS connections reverse-polarity protected.
13) B = inputs and output reverse-polarity protected.
14) C = interference suppression.
15) Uv = 24 V. At Tu < –10 °C warm-up time < 10 min.
16) For optimum performance observe max. warm-up time of 5 minutes
MTTFD 169.1 years
DCavg 0 %
eCl@ss 5.0 27270904
eCl@ss 5.1.4 27270904
eCl@ss 6.0 27270904
eCl@ss 6.2 27270904
eCl@ss 7.0 27270904
eCl@ss 8.0 27270904
eCl@ss 8.1 27270904
eCl@ss 9.0 27270904
eCl@ss 10.0 27270904
eCl@ss 11.0 27270904
eCl@ss 12.0 27270903
ETIM 5.0 EC002719
ETIM 6.0 EC002719
ETIM 7.0 EC002719
ETIM 8.0 EC002719
UNSPSC 16.0901 39121528