Autosimatic - Grupo Luminag

63001057 – Leuze Electronic

63001057 – Leuze Electronic

STOCK: 0.00 unidade(s)
MC336-S1-C02M12-A Magnetically Coded Sensor “Leuze”

FunctionsIntegration in control circuits up to category 4 in accordance with EN ISO 13849-1, Safety system in combination with an evaluation unit such as the MSI-MC310 safety relay or the MSI 400 safety controller.
Characteristic parameters
Mission time20 years, EN ISO 13849-1
CategoryUp to 4, depending on evaluation, 1 sensor connected, EN ISO 13849-1
B10d20,000,000 number of cycles
Electrical data
Protective circuitShort circuit protected, Via e.g. MSI-MC310, MSI 400, Current limitation
Contact allocation1NC + 1NO
Contact typeReed contacts (magnetically sensitive)
Requirement on the voltage supply when used acc. to cULus (UL 508)Class 2 Circuits
Outputs
Max. switching voltage27 V AC/DC
Switching current, max.500 mA
Timing
Response time3 ms
Connection
Number of connections1 Piece(s)
Connection 1
FunctionContact connection
Type of connectionCable with connector
Cable length200 mm
Sheathing materialPVC
Cable colorGray
Thread sizeM12

MaterialMetal
No. of pins4 -pin
Mechanical data
DesignCubic
Dimension (W x H x L)26.2 mm x 13 mm x 36 mm
Housing materialPlastic
Plastic housingGlass fiber reinforced (PPS), self-extinguishing
Net weight94 g
Housing colorRed
Type of fasteningThrough-hole mounting
Installation positionArbitrary, provided housing markings are aligned
Switch typeType 4 interlock device, contactless actuation, EN ISO 14119
Approach actuation directions3-dimensional
Mechanical life time10,000,000 actuation cycles
External actuatorMagnetically coded
Cut-out point (OFF), min.8 mm
Assured cut-out distance (Sar), min.11 mm
Assured cut-in distance (Sao), max.3 mm
Switching tolerance (without ferromagnetic materials in immediate vicinity)-1 … 1 mm
Distance to other magnetic sensors, min.50 mm
Approach speed, min.0.05 m/s
Environmental data
Ambient temperature, operation-20 … 70 °C
Degree of contamination3, EN 60947-1
Certifications
Degree of protectionIP 67
Certificationsc UL US, TÜV Süd (with suitable safety relay)
Test procedure for EMC in accordance with standardEN 60947-5-3, EN 61000-6-2, EN 61000-6-3
Test procedure for oscillation in accordance with standardEN 60947-5-3
Test procedure for shock in accordance with standardEN 60947-5-3
Classification
Customs tariff number90328900
ECLASS 5.1.427272402
ECLASS 8.027272402
ECLASS 9.027272402
ECLASS 10.027272402
ECLASS 11.027272402
ECLASS 12.027274401
ETIM 5.0EC002544
ETIM 6.0EC002544
ETIM 7.0EC002544

REF: 63001057 Categoria: