Autosimatic - Grupo Luminag

LC1DT60AMD – Schneider

LC1DT60AMD – Schneider

STOCK: 0.00 unidade(s)
TeSys D Contactor 4P(4NO) AC-1 <= 440V 60A 220VDC standard coil "Schneider" TeSys D contactor, 4 poles (4NO), for non-inductive load applications up to 60A/690V AC-1. It provides a 220V DC coil with transient suppressor module, 1NO+1NC built-in auxiliary contacts (NC mirror certified), power connection by EverLink BTR screw connectors, control connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (70mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh) Range TeSys TeSys Deca range of product TeSys Deca Product or component typee Contactor Device short name LC1D contactor application Resistive load utilisation category AC-1 Poles description 4P [Ue] rated operational voltage Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC [Ie] rated operational current 60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit [Uc] control circuit voltage 220 V DC Complementary Compatibility code LC1D Pole contact composition 4 NO Contact compatibility M7 Protective cover With [Ith] conventional free air thermal current 10 A (at 60 °C) for signalling circuit 60 A (at 60 °C) for power circuit Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 800 A at 440 V for power circuit conforming to IEC 60947 Rated breaking capacity 800 A at 440 V for power circuit conforming to IEC 60947 [Icw] rated short-time withstand current 320 A 40 °C - 10 s for power circuit 720 A 40 °C - 1 s for power circuit 72 A 40 °C - 10 min for power circuit 165 A 40 °C - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1 80 A gG at <= 690 V coordination type 1 for power circuit 80 A gG at <= 690 V coordination type 2 for power circuit Average impedance 1.6 mOhm - Ith 60 A 50 Hz for power circuit Power dissipation per pole 5.8 W AC-1 [Ui] rated insulation voltage Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 Overvoltage category III Pollution degree 3 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947 Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 Mechanical durability 10 Mcycles Electrical durability 0.7 Mcycles 60 A AC-1 at Ue <= 440 V Control circuit type DC standard Coil technology Built-in bidirectional peak limiting diode suppressor Control circuit voltage limits 0.1...0.3 Uc (-40…70 °C):drop-out DC 0.75...1.25 Uc (-40…60 °C):operational DC 1...1.25 Uc (60…70 °C):operational DC Inrush power in W 19 W (at 20 °C) Hold-in power consumption in W 7.4 W at 20 °C Operating time 42.5...57.5 ms closing 16...24 ms opening Time constant 34 ms Maximum operating rate 3600 cyc/h 60 °C Connections - terminals Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminal 1 1…35 mm² - cable stiffness: flexible without cable end Power circuit: screw clamp terminal 2 1…25 mm² - cable stiffness: flexible without cable end Power circuit: screw clamp terminal 1 1…35 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminal 2 1…25 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminal 1 1…35 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminal 2 1…25 mm² - cable stiffness: solid without cable end Tightening torque Control circuit: 1.7 N.m - on EverLink BTR screw connectors - with screwdriver flat Ø 6 mm Control circuit: 1.7 N.m - on EverLink BTR screw connectors - with screwdriver Philips No 2 Power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25…35 mm² hexagonal screw head 4 mm Power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1…25 mm² hexagonal screw head 4 mm Control circuit: 1.7 N.m - on EverLink BTR screw connectors - with screwdriver pozidriv No 2 Power circuit: 2.5 N.m - on EverLink BTR screw connectors - with screwdriver pozidriv No 2 Auxiliary contact composition 1 NO + 1 NC Auxiliary contacts type Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1 Signalling circuit frequency 25...400 Hz Minimum switching voltage 17 V for signalling circuit Minimum switching current 5 mA for signalling circuit Insulation resistance > 10 MOhm for signalling circuit
Non-overlap time
1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact
mounting support
Rail
Plate
Environment
Standards
CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
IEC 60335-1
product certifications
GL
DNV
BV
UL
RINA
CSA
CCC
GOST
LROS (Lloyds register of shipping)
IP degree of protection
IP20 front face conforming to IEC 60529
Protective treatment
TH conforming to IEC 60068-2-30
Climatic withstand
Conforming to IACS E10 exposure to damp heat
conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device
-40…60 °C
60…70 °C with derating
Operating altitude
0…3000 m
Fire resistance
850 °C conforming to IEC 60695-2-1
Flame retardance
V1 conforming to UL 94
Mechanical robustness
Vibrations contactor open (2 Gn, 5…300 Hz)
Vibrations contactor closed (4 Gn, 5…300 Hz)
Shocks contactor closed (15 Gn for 11 ms)
Shocks contactor open (10 Gn for 11 ms)
height
122 mm
Width
70 mm
Depth
120 mm
Net weight
1.165 kg
Packing Units
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
7.5 cm
Package 1 Width
14.0 cm
Package 1 Length
15.0 cm
Package 1 Weight
1.1 kg
Contractual warranty
Warranty
12 months

REF: LC1DT60AMD Categoria: