Autosimatic - Grupo Luminag

LC1K1610P7 – Schneider

LC1K1610P7 – Schneider

STOCK: 0.00 unidade(s)
Contactor TeSys K 3P AC-3/AC-3e <=440V 16A 1NO "Schneider" 230VAC Coil TeSys K is a compact contactor range with a wide variety of coil voltage and terminal connection options The offer features specific versions for railway (TeSys S207) and electrodomestic (TeSys S335) applications. One of the smallest contactor offerings in the market. The range delivers strong performance for its compact size and promises seamless integration in all applications. Widely used for industry, infrastructure and building applications TeSys K contactor, 3 poles (3NO), for motor control applications up to 16A/690V AC-3 (7.5kW@400V). It provides a 230V 50/60Hz AC coil, 1NO built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh) Contactor application Motor control Complementary Utilisation category AC-3 AC-1 AC-3e Poles description 3P power pole contact composition 3 NO [Ue] rated operational voltage Power circuit: 690 V AC 50/60 Hz Signalling circuit: 690 V AC 50/60 Hz [Ie] rated operational current 16 A at <= 440 V AC-3 for power circuit 20 A at <= 690 V AC-1 for power circuit 16 A at <= 440 V AC-3e for power circuit Control circuit type AC at 50/60 Hz [Uc] control circuit voltage 230 V AC 50/60 Hz Motor power kW 4 kW at 480 V AC 50/60 Hz 4 kW at 500...600 V AC 50/60 Hz 4 kW at 660...690 V AC 50/60 Hz 5.5 kW at 440 V AC 50/60 Hz 4 kW at 220...230 V AC 50/60 Hz 7.5 kW at 380...415 V AC 50/60 Hz Auxiliary contact composition 1 NO [Uimp] rated impulse withstand voltage 8 kV Overvoltage category III [Ith] conventional free air thermal current 20 A (at 50 °C) for power circuit 10 A (at 50 °C) for signalling circuit Irms rated making capacity 110 A AC for signalling circuit conforming to IEC 60947 160 A AC for power circuit conforming to NF C 63-110 160 A AC for power circuit conforming to IEC 60947 Rated breaking capacity 110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947 [Icw] rated short-time withstand current 115 A 50 °C - 1 s for power circuit 105 A 50 °C - 5 s for power circuit 100 A 50 °C - 10 s for power circuit 75 A 50 °C - 30 s for power circuit 55 A 50 °C - 1 min for power circuit 50 A 50 °C - 3 min for power circuit 25 A 50 °C - >= 15 min for power circuit
80 A – 1 s for signalling circuit
90 A – 500 ms for signalling circuit
110 A – 100 ms for signalling circuit
Associated fuse rating
25 A gG at <= 440 V for power circuit 25 A aM for power circuit 10 A gG for signalling circuit conforming to IEC 60947 10 A gG for signalling circuit conforming to VDE 0660 Average impedance 3 mOhm - Ith 20 A 50 Hz for power circuit [Ui] rated insulation voltage Power circuit: 600 V conforming to UL 508 Power circuit: 690 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-5-1 Signalling circuit: 600 V conforming to UL 508 Power circuit: 600 V conforming to CSA C22.2 No 14 Signalling circuit: 600 V conforming to CSA C22.2 No 14 Insulation resistance > 10 MOhm for signalling circuit
Inrush power in VA
30 VA (at 20 °C)
Hold-in power consumption in VA
4.5 VA (at 20 °C)
Heat dissipation
1.3 W
Control circuit voltage limits
Operational: 0.8…1.15 Uc (at <50 °C) Drop-out: 0.2...0.75 Uc (at <50 °C) Connections - terminals Screw clamp terminals 1 cable(s) 1.5…4 mm²solid Screw clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable end Screw clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable end Screw clamp terminals 2 cable(s) 1.5…4 mm²solid Screw clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable end Screw clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end Maximum operating rate 3600 cyc/h Auxiliary contacts type Type instantaneous 1 NO Signalling circuit frequency <= 400 Hz Minimum switching current 5 mA for signalling circuit Minimum switching voltage 17 V for signalling circuit Mounting support Plate Rail Tightening torque 0.8…1.3 N.m - on screw clamp terminals Philips No 2 0.8…1.3 N.m - on screw clamp terminals flat Ø 6 mm 0.8…1.3 N.m - on screw clamp terminals pozidriv No 2 Operating time 10...20 ms coil de-energisation and NO opening 10...20 ms coil energisation and NO closing Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 Non overlap distance 0.5 mm Mechanical durability 10 Mcycles Electrical durability 1.3 Mcycles 16 A AC-3 at Ue <= 440 V 1.3 Mcycles 16 A AC-3e at Ue <= 440 V Mechanical robustness Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Height 58 mm Width 45 mm Depth 57 mm Net weight 0.18 kg Environment Standards EN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1 Product certifications CB Scheme CCC UL CSA EAC CE UKCA IP degree of protection IP2X conforming to VDE 0106 Protective treatment TC conforming to IEC 60068 TC conforming to DIN 50016 Ambient air temperature for operation -25…50 °C Ambient air temperature for storage -50…80 °C Operating altitude 2000 m without derating Flame retardance V1 conforming to UL 94 Packing Units Unit Type of Package 1 Db Number of Units in Package 1 1 Package 1 Height 4.5 cm Package 1 Width 6.0 cm Package 1 Length 6.5 cm Package 1 Weight 179.875 g Unit Type of Package 2 S02 Number of Units in Package 2 50 Package 2 Height 15.0 cm Package 2 Width 30.0 cm Package 2 Length 40.0 cm Package 2 Weight 9.232 kg Unit Type of Package 3 P06 Number of Units in Package 3 800 Package 3 Height 75.0 cm Package 3 Width 80.0 cm Package 3 Length 60.0 cm Package 3 Weight 155.708 kg

REF: LC1K1610P7 Categoria: