OGD597 – Ifm
STOCK: 0.00 unidade(s)
OGDLFNKG/IO-Link/US Photoelectric Distance Sensor “Ifm”
Small compact design with standard M18 thread and PMD time-of-flight technology
Measurement to the nearest millimetre and monitoring of distances in the running process
Distance value shown on 2-colour display and sent via IO-Link
Easy setting with 3 buttons or IO-Link
Type of light red light
Laser protection class 1
Application
Application [m] 0.03…0.3
Electrical data
Operating voltage [V] 10…30 DC; (operating voltage “supply class 2” according to cULus)
Current consumption [mA] < 75
Current consumption reference voltage [V] 24
Protection class III
Reverse polarity protection yes
Type of light red light
Wave length [nm] 650
Typ. lifetime [h] 50000
Outputs
Electrical design NPN
Output function 2 x normally open / normally closed; (parameterisable)
Permanent current rating of switching output DC [mA] 100; (per output)
Type of short-circuit protection pulsed
Overload protection yes
Detection zone
Range [mm] 25...300
Max. light spot width [mm] 3
Max. light spot height [mm] 3
Light spot dimensions refer to at maximum range
Background suppression [m] 0.03...19.2
Measuring/setting range
Measuring range [m] 0.025...0.3
Sampling rate [Hz] 33
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles Smart Sensor: Sensor Identification; Binary Data Channel; Process Value; Sensor Diagnosis
SIO mode yes
Required master port type A
Process data analogue 2
Process data binary 2
Min. process cycle time [ms] 6
Supported DeviceIDs
Type of operation
DeviceID
Default
1066
Operating conditions
Ambient temperature [°C] -25...50
Note on ambient temperature
In ambient temperatures < -10 °C a warm-up time is necessary.
Laser is off.
Storage temperature [°C] -30...80
Protection IP 65; IP 67
Tests / approvals
EMC
EN 60947-5-2
Laser protection class 1
Notes on laser protection
Caution:
laser light
laser class:
1
EN / IEC60825-1:2007
EN / IEC60825-1:2014
Complies with 21 CFR 1040 except for deviations pursuant to Laser Notice No. 50, dated June 2007.
MTTF [years] 159
Mechanical data
Weight [g] 205.5
Dimensions [mm] 61.7 x 22.5 x 45.2
Materials Housing: stainless steel (1.4404 / 316L); PPSU; ABS; PMMA; PBT / PC; EPDM; front lens: glass
Displays / operating elements
Display
switching status
2 x LED, yellow
1 x alphanumeric display, 3-digit
Accessories
Items supplied
lock nuts: 2
Remarks
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A
Diagrams and graphs
a:
sensor
b:
object
c:
background
x:
distance sensor/object [mm]
y:
min. distance object/background [mm]
hysteresis graph
x:
distance sensor/object [mm]
y:
min. distance object/background [mm]
1 =
background (black 6 % remission)
2 =
background (white 90 % remission)
Other data
Parameter
Setting range
Factory setting
OU1
Hno, Hnc, Fno, Fnc, OFF
Hno
SP1 [mm]
30...300
300
nP1 [mm]
30...300
90
FSP1 [mm]
30...300
110
OU2
Hno, Hnc, Fno, Fnc, OFF
Hno
SP2 [mm]
30...300
30
nP2 [mm]
30...300
190
FP2 [mm]
30...300
210
dS1 [s]
0...0.1...5
0
dr1 [s]
0...0.1...5
0
dS2 [s]
0...0.1...5
0
dr2 [s]
0...0.1...5
0
dFo [s]
0...0.1...5
0.1
dIS
ON / OFF
ON
Repeatability: 6 s
repeatability of the measured values
distance
white (90 % remission)
black (6 % remission)
25...300 mm
2.0 mm
5.0 mm
The values apply at
Extraneous light on the object
< 10 klx
constant ambient conditions
23 °C / 960 hPa
minimum power-on time in minutes