Autosimatic - Grupo Luminag

PX-10CP – Keyence

PX-10CP – Keyence

STOCK: 0.00 unidade(s)
Heavy-Duty Sensor Amplifier Connector Type PNP “Keyence”

Response time
500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA)
Output selection
LIGHT-ON/DARK-ON
Indicator lamp
– Operation indicator:Red LED x 2, DSC orange LED x 1
– Dual digital monitor:Dual 7-segment display
[Preset value (4-digit green LED) and current value (4-digit red LED) illuminated together,
current value range:0 to 65504, excess gain:0 P to 999 P]
– Hold function:Possible to display both peak and bottom hold values. Selectable from 5 variations.
– Bar LED monitor [Excess gain displayed (85% to 115% in 7 steps)]
– Scaling display
Detection mode
Light intensity (automatic sensitivity-tracking function provided)/ [Limit light intensity/output monitor]
Shift function
Variable between –1999 and 9999
Timer function
Timer OFF/OFF-delay/ON-delay/One-shot/ON-delay, OFF-delay/ON-delay, One-shot
Timer duration selectable:1 ms to 9999 ms
Maximum error against the setting value:10% max.
Control output
PNP open-collector 30 V, 100 mA max. for an output/100 mA max. for two outputs, residual voltage 1 V max.
External input
Interference prevention
Up to 4 units (in all power modes)*1
Rating
Power voltage
12 to 24 VDC, Ripple (P-P) 10 % or less, Class2*2
Power consumption
Standard mode:50 mA max. at 24 V/55 mA max. at 12 V
Power saving mode:40 mA max. at 24 V/45 mA max. at 12 V
Environmental resistance
Enclosure rating
IEC: IP67/JEM: IP67/NEMA: 4X
Ambient temperature
-10 to +55 °C 14 to 131 °F (No freezing)*3
Relative humidity
35 to 85 % RH (No condensation)
Vibration resistance
10 to 55 Hz, Double amplitude 1.5 mm 0.06″, 2 hours in each of the X, Y, and Z directions
Case material
Housing:PBT, display:PSU, display cover/connector cover:SUS304, radiator plate:SUS304, gasket:NBR
Weight
Approx. 50 g
*1 The received light intensity may vary somewhat when the sensor head’s cable layout is changed, so redo the sensitivity setting when changing the layout. The interference prevention function is affected
somewhat when using multiple units installed adjacent to each other. Fine-tune the sensitivity (increase the setting) for adjacent layouts.
*2 Use a 24 VDC power voltage when using a head light transmitting cable of 3 m 9.8′ or more (PX-H71/H71TZ) or 10 m 32.8′ or more (PX-H72).
*3 When using multiple units connected adjacently, the ambient temperature varies with the conditions below.
2 to 4 Units: -10 to +50 °C 14 to 122 °F, 5 to 17 Units: -10 to +45 °C 14 to 133 °F

REF: PX-10CP Categoria: